欢迎来到我的范文网!

外墙修补滚涂透明防水涂料施工方案

工程考试 时间:2020-09-21

【www.myl5520.com--工程考试】

墙面修补方案
篇一:外墙修补滚涂透明防水涂料施工方案

目 录

1 编制依据.................................................................................................................... 2

2 工程概况.................................................................................................................... 2

3 原因及处理措施........................................................................................................ 2

3.1墙面裂缝............................................................................ 错误!未定义书签。

3.2墙面空鼓.............................................................................................................. 2

4 施工部署.................................................................................................................... 3

4.1墙面裂缝修补方法.............................................................................................. 3

4.2梁、柱与砌体交接处裂缝修补方法.................................................................. 3

4.3涂料裂缝修补方法.............................................................................................. 3

4.4假缝修补方法...................................................................................................... 4

4.5动力站裂缝修补方法.......................................................................................... 4

4.6墙面空鼓修补方法.............................................................................................. 5

5 施工准备.................................................................................................................... 6

5.1 材料准备 ............................................................................................................. 6

5.2 人员准备 ............................................................................................................. 6

6 施工方法.................................................................................................................... 6

6.1吊篮安装注意事项.............................................................................................. 6

6.2悬挂机构二次转移安装...................................................................................... 7

6.3吊篮的拆卸.......................................................................................................... 7

7 安全防护措施............................................................................................................ 8

8 安全生产事故风险分析............................................................................................ 8

9 文明施工措施............................................................................................................ 8

1 编制依据

1.1 工程设计施工图纸

1.2 《建筑施工手册》(第五版)

1.3 《建筑工程施工质量验收统一标准》GB50300-2013

1.4 《建筑装饰装修工程施工质量验收规范》GB 50210—2011

1.5 国家建筑标准设计图集05J909以及其它国家现行规范、规程、标准。

2 工程概况

本子项工程为*****************工程。建筑面积为** m2,建筑外墙0.200m以上采用蒸气加压混凝土砌块,砌筑砂浆为Mb7.5专用砂浆。外墙装饰采用丙烯酸耐候性涂料。2013年11月完成涂料施工,至今外墙表面出现多处裂缝、空鼓现象。主要位置出现在现浇结构与砌筑部分裂缝沿交界线分布,现浇梁底面的贯通裂缝及其他位置无规则分布。

3 原因及处理措施

3.1形成原因

——加气块填充墙未按规范施工,一次性砌筑过高;

——加气块填充墙墙顶与上部现浇结构梁未配置砖斜砌顶紧;

——不同材料的墙体交接处未加钉金属网;

——砌体灰缝厚度不满足规范要求;

——填充墙体与砼交接处未按图纸和规范要求加拉结钢筋或拉结筋的长度过短、间距过大无法满足规范要求。

3. 2处理措施

先去除裂缝处面层并凿槽,清理干净后填补修补材料,最后将面漆修复。

3.2墙面空鼓

3.2.1形成原因

——填充墙体与砼交接处未按图纸和规范要求加拉结钢筋,沿交接缝处出现裂缝,以及由于砌体结构裂缝的原因导致抹灰开裂。

——基层处理不当或未清理干净。

——基层浇水不足,抹灰砂浆脱水,影响粘结力。

——未按操作规程分层抹灰,造成每遍灰的收缩变形集中到面层,加大了几倍的变形量。 ——原材料质量不好。

——砂浆配制不好,使用不当。

——水泥砂浆抹在石灰砂浆或混合砂浆上。

3.2.2处理措施

若需去除空鼓部分,则先进行切割凿出墙面空鼓部分(范围为空鼓部位四周扩大100mm),基层清理干净后挂铁丝网片,最后做墙面修补,修复至原样。

若不需去除空鼓部分,则需在打磨涂层后,涂刷防水涂料,最后做墙面修补。

4 施工部署

施工前要先观察天气预报,选择晴天时进行施工。

4.1墙面裂缝修补方法

4.1.1面漆打磨

采用角磨机沿裂缝方向磨去外墙涂层,打磨宽度100mm。

4.1.2 刷防水涂料

在打磨位置刷水泥基防水涂料。

4.2梁、柱与砌体交接处裂缝修补方法

4.2.1面层凿除

先将开裂处抹灰层凿除,四周凿成方块形,清理基层,将松动、疏松、脱落的砂浆清除干净。

4.2.2挂铁丝网

在不同材料基体交接处的表面重新粘贴镀锌铁丝网,之后才采用水泥浆掺建筑胶的方法对墙面进行扫毛处理。镀锌铁丝网采用A1铁丝,网眼大小20×20mm。外墙修补滚涂透明防水涂料施工方案。

4.2.3待扫毛的水泥浆终凝后,用水将墙面适当湿润,然后分两次用和原面层相同材料的1:2 水泥砂浆填补并槎平。

4.3涂料裂缝修补方法

4.3.1批刮腻子

批刮腻子前,检查墙面抹灰有无裂纹、空鼓,确保无质量问题后进行下一步施工。

满批刮第一遍腻子时厚度需控制在1-2mm以下;待腻子干透后用砂布清除腻子表面的刮板痕迹,毛刺等,再批刮第二遍腻子;检查基面腻子层,对损坏部分进行修补。

4.3.2打磨

打磨新修补与原外墙面的接茬处,确保表观平整。

4.3.3滚涂底漆

上底漆前需确认:墙面湿度不大于8%;表面灰尘已清干净;防止交叉污染。做好保护,防止对成品及半成品的污染;采用与原图层相同底漆,涂刷时,要做到滚涂均匀,按照先角、边,再大面的施工方法进行;底漆不得漏漆和流坠;及时清理粘在墙上的异物。干燥时间24h方可进行下一步施工。

4.3.4涂刷面漆

用专业稀释剂按产品说明书要求比例搅兑,并视现场气候静止15分钟时间,让涂料反应完全。用搅拌枪搅拌均匀;面漆必须在干燥的底漆上滚涂;先刷边角及不易喷涂的部位,再由上往下进行面漆施工;第二遍面漆必须在第一遍面漆完全干燥后施工。湿膜表面必达到均匀、无漏底、无针孔、无流挂、无皱纹等不良现象。

4.4假缝修补方法

4.4.1面漆打磨

采用角磨机沿裂缝方向磨去外墙涂层,打磨宽度100mm。

4.4.2凿槽

沿裂缝剔槽或切割V形槽,并清理槽内灰尘。

4.4.3填补

用防水嵌缝密封胶添补裂缝处,平整度要好。

4.4.4面漆修补

刷与原面漆相同批次或相同颜色、材质面漆。

4.5动力站裂缝修补方法

4.5.1面漆打磨

采用角磨机沿裂缝方向磨去外墙涂层,打磨宽度100mm。

4.5.2凿槽

沿裂缝剔槽或切割V形槽,并清理槽内灰尘。

4.5.3封闭底漆

涂刷封闭底漆,以增加槽内附着力。

4.5.4腻子批填

用腻子添补裂缝处,无开裂,平整度要好。

4.5.5面漆修补

刷与原面漆相同批次或相同颜色、材质面漆。

4.6墙面空鼓修补方法

当空鼓面积大于等于0.02m2时,需要将空鼓部分去除后再做修补。若空鼓面积小于0.02m2,则不需切割、开凿空鼓部分。

4.6.1需切割空鼓的修补处理

4.6.1.1施工流程

切割、凿除空鼓→挂防裂网→洒水湿润→基层抹灰→面层抹灰→砂浆找平→养护。

4.6.1.2切割、凿除空鼓

沿空鼓四周进行机械切割(范围为空鼓部位四周扩大100mm),使切割部位形成较整齐规则的平面,四周切割边切成向外约45度的斜口,而后人工轻轻凿除空鼓砂浆至墙体砖面或不空鼓的底层砂浆面,用钢丝刷刷除松动部位,确保表面洁净,无浮浆、油污。

4.6.1.3挂铁丝网

不同基体材料交接处挂镀锌铁丝网,将防裂网钉挂在墙面上,镀锌铁丝网采用A1铁丝,网眼大小20×20mm。如需搭接,搭接长度不小于150mm。

4.6.1.4洒水湿润

用水将墙体湿润,喷水要均匀,不得遗漏。

4.6.1.5基层抹灰

用9mm厚1:3水泥砂浆抹底灰并扫毛,砂浆均需采用机械搅拌,搅拌时间不少于180s。

4.6.1.6砂浆找平

6mm厚1:2.5水泥砂浆表面抹光找平。应注意在抹面层灰以前,应先检查底层砂浆有无空、裂现象,如有空裂,应剔凿返修后再抹面层灰;另外应注意底层砂浆上的尘土、污垢等应先清净,浇水湿润后,方可进行面层抹灰。外墙修补滚涂透明防水涂料施工方案。

4.6.1.7养护

水泥砂浆抹灰层应浇水养护。

4.6.2不需切割空鼓的修补方法

涂膜防水施工方案
篇二:外墙修补滚涂透明防水涂料施工方案

目 录

1、编制依据 ..................................................................................................................................... 1

1.1相关规范 ............................................................................................................................. 1

1.2图纸 ..................................................................................................................................... 1

2、工程概况 ..................................................................................................................................... 1

3、材料要求及机具准备 ................................................................................................................. 1

3.1、材料要求 .......................................................................................................................... 1外墙修补滚涂透明防水涂料施工方案。

3.2、主要机具 .......................................................................................................................... 1

4、施工工艺流程 ............................................................................................................................. 2

4.1、空调机房及其他用水房间 .............................................................................................. 2

4.2、卫生间、开水间 .............................................................................................................. 2

5、施工做法 ..................................................................................................................................... 2

5.1、材料及机具准备 .............................................................................................................. 2

5.2、施工做法 .......................................................................................................................... 2

6、质量要求及注意事项 ................................................................................................................. 4

6.1、质量要求 .......................................................................................................................... 4

6.2施工注意事项 ..................................................................................................................... 4

7、质量检验及工程验收 ................................................................................................................. 5

8、安全、消防保证措施 ................................................................................................................. 5

1、编制依据

1.1相关规范

2、工程概况

Xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx

涂膜防水面积为1265.68㎡,采用满刷1.5mm聚氨酯涂料。

3、材料要求及机具准备

外墙修补滚涂透明防水涂料施工方案。

3.1、材料要求

单组份聚氨脂防水涂料的优点是重量轻;耐侯性、耐水性、耐蚀性优良且适用性强,对于各种形状的部位均可涂布形成无缝的连续封闭的防水膜;但是人工涂刷,涂布厚度不易做到均匀一致,且材料抵抗结构变形的能力差,与潮湿基层的粘结力差等不足之处,因此要求聚氨脂材料必须具有良好的耐水性、耐久性、耐腐蚀性及耐菌性且有较好的延伸性及较大适应基层变形能力。

聚氨脂防水涂料属反应型高档有机涂料,涂料等原材料进场应检查其产品合格证、产品说明书,经复检合格后方可使用。

3.2、主要机具

施工机具包括拌料桶、小型油漆桶、橡皮刮板或塑料刮板、铁皮小刮板、油漆刷、圆滚刷、小抹子、油工铲刀等。

4、施工工艺流程

4.1、空调机房及其他用水房间

基层处理→涂刷聚氨酯底涂料→局部增强→涂刷聚氨酯防水涂料(图纸要求)→蓄水实验(合格)→垫层及基础施工。

4.2、卫生间、开水间

基层处理→涂刷聚氨酯底涂料→局部增强→涂刷聚氨酯防水涂料(图纸要求)→蓄水实验(合格)→20厚1:3干硬性水泥砂浆结合层表面撒素水泥粉→贴地砖保护→蓄水实验(合格)。

涂布顺序应遵循“先远后进、先高后低、先细部后大面、先立面后平面”的原则,且每层涂抹方向应相互垂直。

5、施工做法

5.1、材料及机具准备

施工前应预先准备好各种材料及施工机具,并对各种机具进行检查其工作性能,施工操作人员经现场管理人员进行交底并且领悟防水操作要点后方可施工,严禁现场操作人员野蛮施工。

5.2、施工做法

1、基层处理

(1)堵洞:各种管道套管安装之后,用膨胀细石混凝土塞实填平。

(2)找平层:用1:3水泥砂浆找平,做到平整、坚实、无麻面、起砂、起壳、松动及凹凸不平现象;砖墙灰缝应与砖墙表面抹平;除去基层表面的浮灰和其它突出的东西,用不收缩砂浆抹平孔洞、蜂窝以及细微裂缝等缺陷;用2米直尺检查基层表面平整度,偏差不得超过5mm;若基层上存在裂缝,则应做附加处理。

(3)找平层与突出平面基层的结构(如立墙、变形缝、管道、天窗等)及地下室底板找平层与立墙、集水坑、电梯井等交接处的阴阳角均应做成半径为20mm的圆弧或45°(135°)折角;厕浴间泛水坡度应在2%以上,不得有局部积水;在转角处要抹成小圆角;与找平层相连接的管件、卫生洁具、地漏、排水口等必须安装牢固、收头圆滑。这些设备必须安装完毕,才能进行防水层的施工;

(4)将基层清扫干净,基层要做到找坡正确,排水顺畅,表面平整、坚实,无起灰、起砂、起壳及开裂等现象,涂刷底层涂料前,基层表面必须达到干燥状态。

2、涂刷底层涂料(即聚氨脂底胶)

基层处理剂为低粘度聚氨脂,可起到隔离基层潮气,提高涂膜与基层粘结强度的作用。先涂阴阳角、管道根部均匀涂刷一遍,然后大面积涂刷,用料为0.15~0.20kg/m2。涂刷应固化干燥24h以上(具体时间应根据施工温度测定),才能进行下一道工序的施工。

3、增强涂布

(1)增强涂布在涂刷底层涂料后进行,在地漏、管道根部、阴阳角、排水口、施工缝、变形缝等容易渗漏部位,均匀涂刷一遍做附加层。

(2)增强涂布与基层涂料是组成涂膜防水层的最初涂层,对防水层的抗渗性能具有重要作用,因此涂布操作时要认真仔细,不得有气孔、鼓泡、折皱、翘边等质量问题。

(3)节点处理的方法为立管固定用细石砼封堵以后,管根四周抹成八字脚,将管根及周围务必清理干净、干燥。在管根口周围,涂刷基层处理剂,再做聚氨酯防水涂料增强层,并在立管上涂刷涂料,使立管和混凝土基层成为一体。

4、涂膜施工

(1)在前一层涂料固化干燥后,应先检查其上有无残留的气孔或气泡,如无,即可涂布施工;如有,则应用橡胶板刷将混合料用力压入气孔填实补平,然后再进行第一道涂膜施工。

(2)用滚刷在水平基层面上和垂直基面上涂布涂料;应涂刷均匀、厚薄一致应分层分遍涂布涂料。一般可分1-2遍完成,重涂时间的间隔,由施工时的温度和涂膜固化的程度(以手触不粘)来确定。为了确保防水工程质量,涂刮的方向必须与前一层的涂刮方向垂直。施工后在防水层未固化前不宜上人踩踏。

5、第一次蓄水实验

待防水层完全干燥后,可进行第一次蓄水实验,蓄水3cm,蓄水24h后无渗漏时为合格。

6、贴地砖保护

防水层蓄水实验不漏,质量检查合格后,即可在防水层上做30厚1:3干硬性水泥砂浆结合层表面撒素水泥粉并进行卫生间贴地砖保护。施工时注意成品保护,不得破坏防水层。

7、第二次蓄水实验卫生间装饰工程完工后,工程竣工前进行第二次蓄水实验,以检验防水层是否被破坏,如果蓄水实验合格,卫生间防水施工才算成功。

6、质量要求及注意事项

6.1、质量要求

1、涂膜防水层不得有渗漏水现象,排水系统应顺畅。

2、所采用的涂料应符合质量标准和设计要求。

3、基层不得有酥松、起砂、起皮现象。

4、涂膜防水层不应有漏底、开裂、孔洞等缺陷以及脱皮、鼓泡、露胎体和皱皮等现象,涂膜防水层与基层之间应粘结牢固,不得有空鼓、砂眼、脱层等现象。厚度应符合设计要求。

5、 收头部位的密封处理应连续、封闭。

6、 刚性保护层与涂膜防水层之间应设置隔离层。操作人员应严格保护已做好的涂膜防水层。在做保护层之前任何人员不得进入施工现场,以免损坏防水层。

7、 涂膜防水层表面坡度应符合设计要求,不应有局部积水和渗漏水的现象存在。

8、 地漏或排水口等部位不有杂物堵塞,确保排水畅通。施工时,涂膜材料不要污染已做好饰面的墙壁、卫生洁具、门窗等。

6.2施工注意事项

1、当涂料粘度过大,不便进行刮涂施工时,可加入少量的专用稀释剂进行稀释,以降低粘度。

2、气孔、气泡:材料搅拌方式及搅拌时间未使材料拌合均匀;施工时应采用功率、转速不过高的搅拌器。另一个原因是基层处理不洁净,做涂膜前应仔细清理基层,不得有浮砂和灰尘,基层上更不应有孔隙,涂膜各层出现的气孔应按工艺要求处理,防止涂膜破坏造成渗漏。

3、起鼓:基层有起皮、起砂、开裂、不干燥,使涂膜粘结不良;基层施工应认真操作、养护,待基层干燥后,先涂底层涂料,固化后,再按防水层施工工艺逐层涂刷。

4、涂膜翘边:防水层的边沿、分项刷的搭接处,出现同基层剥离翘边现象。主要原因是基层不洁净或不干燥,收头操作不细致,密封不好,底层涂料粘结力不强等造成翘边。故基层要保证洁净、干燥,操作要细致。

5、破损:涂膜防水层分层施工过程中或全部涂膜施工完,未等涂膜固化就上人操作活动,或放置工具材料等,将涂膜碰坏。划伤。施工中应保护涂膜的完整。

墙体渗水维修施工方案
篇三:外墙修补滚涂透明防水涂料施工方案

外墙渗水维修

施工方案

一、 工程概况:

本工程***小区住宅楼,层高16层,属于高层建筑,渗水部位大部分为连体铝合金窗框及四周墙体。渗水原因主要是楼层高,楼体自重荷载大,地基下沉导致外墙开裂,雨水沿裂缝渗进外墙瓷砖砂浆层,砂浆层里面的水达到饱和后,由于重力及压力作用顺着墙体裂缝渗进内墙。

因为是高层建筑,防水维修客观存在很大难度及维修工人自身安全风险,施工环境受到制约。本着防水维修的根本目的就是为业主排忧解难,尽量减少由于渗水导致业主的财物及精神损失,最终解决渗漏水问题,因此再大的难度,也要精益求精,维修到位。

二、 施工工艺及步骤:

由于每个窗框渗水位置及程度不同,渗水原因也比较复杂,因此勘查漏点,是最关键的第一步。维修方案的制定是引导维修的技术指导,从哪个部位修,怎么修,每道工序都得仔细到位。

工序:漏点勘查分析→方案制定→吊绳及安全防护→裂缝查找→裂缝凿洗→嵌缝堵漏→瓷砖砖面滚涂→检查→恢复→工完场清。

1. 漏点勘查分析

根据同物业、业主对漏点进行仔细勘察、分析出原因,找到漏点的位置,当场确定维修方法;

2. 方案制定

针对不同的防水难点,用什么方法维修,用哪种防水材料,各种情况考虑周全,然后与公司工程技术员商定技术方案,制成书面的文件,交与公司总工审核之后,对现场施工人员技术交底。

3. 施工准备

⑴ 人员配置

外墙高空吊绳作业,必须配备既能最大限度节约劳动力成本,又要能保证施工安全、质量、紧奏有序开展作业的人员要求,所以一处吊绳作业必须配备三个工人。

⑵ 材料准备

防水材料配备充足。水不漏、纯丙防水胶泥、DPS透明防水剂、硅胶、注浆液及针头等,都采用正规合格产品,以保证防水效果。

⑶ 机具置配

施工机具的配备齐全是防水施工提高经济效益的保证。此处维修需配备的机具有:吊绳、安全绳、安全带、电锤、电镐、电钻、注浆机等。

4. 裂缝处理

对于外墙面砖裂缝比较宽,或者瓷砖起壳松动的,就必须凿开裂缝。高空外墙裂缝处理,是一件难度很大的施工作业,凿开裂缝需小心翼翼,严禁砼及瓷砖碎块溅落,所以安全防护网必须铺设牢固,做到万无一失。凿开裂缝清洗干净后,用水不漏嵌缝堵漏,再用防水砂浆抹平。

5. 铝合金窗边框无混凝土结构连接防水处理

部分无混凝土连接的铝合金窗边防水处理是一种比较有难度的施工,此处也是渗漏水的薄弱部位,铝合金边框的连接靠无防锈处理的扁铁及地脚螺栓固定,外口砂浆层覆盖,90度阴角硅胶密封,本来砂浆保护层无防水作用, 经过一段时间扁铁生锈膨胀,砂浆保护层开裂,雨水顺裂缝渗进扁铁连接部位,此时扁铁生锈更厉害。雨水大的时候雨水就源源不断渗进,从铝合金窗空心边柱顺流而下,导致连体窗最下一层渗漏最严重。此处维修必须要施工人员坐吊绳仔细勘察,找到与此处贯通的外墙瓷砖裂缝,如果此处外墙面砖松动必须凿开,凿至现浇层,露出扁铁及螺栓,清洗干净基层后,采用水不漏堵塞,堵塞必须到位不留缝隙,待水不漏干透后,所有接口及面层再涂刷防水膏。如果此处面砖无松动,只是细小裂缝,就在面积大的范围直接涂刷防水膏,防止第一遍涂刷不到位或者由于干固收缩粘结不牢固,一遍刷好待其两个小时干透后再涂刷一遍。

外墙防水涂料分两种:一种是液态的,对于外墙细小裂缝是有效果的,涂刷后防水涂料渗进裂缝,干固结膜后,能填满裂缝,从而阻止雨水渗进内墙;另一种是膏状防水泥,此种材料具有附着力强、耐老化,有弹性,干固后透明、能抗击由于温差变化大引起的热胀冷缩。能修补10mm以下外墙裂缝,裂缝里填满防水膏,一遍干固后涂刷二遍能起到立竿见影的防水效果。

6.注浆防水

注浆防水是一种只能针对混凝土裂缝的防水方法,例如,现浇楼板、地下室底板、卫生间楼地板等。此方法是将一种遇水起化学反应膨胀凝固的液态材料,利用高压注浆机灌注混凝土裂缝,遇水膨胀凝固后,从而堵住渗漏水。雅宾利外墙及卫生间部分漏水,将采取这种方法维修。

7.检验

外墙及窗框检验防水效果,得至少下过一、二场大雨后,观察渗漏点是否还渗漏,才能定论是否完好。

8.工完场清

对于施工留下的建筑垃圾,及时清理,保持施工现场干净整洁。

三、 吊绳维修安全措施:

吊绳高空作业人员必须是经过安全知识培训,领取登高作业资格证,

且人证相符的人员。确定漏点以后吊绳绳索运至屋顶(必须两人),要搬运两根绳索,一个主吊绳,一根安全绳。将绳索绑扎牢靠后,安放绳索,一人坐吊,一人看护绳索及传递防水材料和工具,看护人员最重要的工作是防止由于绳索晃动与墙阳角摩擦,割破绳索。坐吊工人降至维修部位,进行维修。此时地面得安排一人,将施工的坠落半径用安全警示围挡,防止人员及车辆进入危险范围。

四、文明施工

1、 外墙防水工程按照安全文明工地管理的要求组织施工,防止高空作业人员携带的工具及防水材料掉落,伤及人员及损坏底层业主家突出窗外的物品。

2、 文明施工管理:进入业主家必须戴鞋套,严禁赤脚、光膀子、施工工具轻拿轻放;不小偷小摸,并对在业主家施工完成后的垃圾清理干净。

上海凌云防水装饰工程有限公司

外墙涂料专项施工方案
篇四:外墙修补滚涂透明防水涂料施工方案

外墙涂料装饰工程

编制单位:编制日期:2015年6月30日

施工方案报审表

工程名称:

本表一式三份,由承包单位填写,经监理审批后。建设、承包、监理单位各存一份

施工方案目录

一、编制依据

二、工程概况

三、施工准备

四、施工工艺

五、质量要求

六、成品保护措施

七、质量保证措施

八、安全保证措施

一、编制依据

1、《建筑工程施工质量验收统一标准》(GB50300-2001)

2、《建筑装饰装修工程质量验收规范》(GB50210-2001)

二、工程概况

工程名称:

建设单位:

监理单位:

总承包单位:施工单位:

工程地址:

三、施工准备

1、根据外墙涂料材料定样要求,枣庄茂民装饰工程有限公司提供质量证明文件,材料进场由甲方及监理单位派专人进行进场验收,合格后方可使用。

2、基层的碱度PH值在10以下,同时基层已干燥,湿度低于10%;基层表面平整,阴阳角及角线密实,轮廓分明;墙面无渗水、无裂缝、空鼓、起泡空洞等结构问题。

3、施工条件: (1)基层抹灰完成后进行检查,合格后方可进行施工。

(2)外墙涂料由于是水性涂料,对施工保养条件较高。施工温度要求高于5℃低于35℃,环境湿度低于75%,以保证成膜良好。

(3)低温将引起涂料的漆膜粉化开裂等问题,环境湿度大使漆膜长时间不干,并最终导致成膜不良。

(4)基层涂刷涂料时,含水率不得大于10%。在施工时若没有测含水率的手段,可以在基层表面放一块1m2卷材,静置3~4小时以后掀开检查,基层覆盖部位与卷材上未见水印即可铺设。

(5)门窗安装已完成,经检查合格,门窗框四周与墙之间的缝隙堵抹应符合规范要求。

(6)墙面的设备管洞已处理完毕,为确保墙干燥,各种穿墙孔洞应提前抹灰补齐,墙面基层